| Sign In | Join Free | My chinalane.org | 
 | 
Brand Name : Dewei
Model Number : DWX-50701
Certification : ISO CE CFDA
Place of Origin : China
MOQ : 500 units
Price : Negotiable
Payment Terms : L/C, T/T, Western Union
Supply Ability : 20,000L/day
Delivery Time : in 20 days
Packaging Details : 20L,500ml,5L
Type : Diluent Lyse Rinse
Store Condition : Room Temperature
Usage : Clinical Experiments
Specimen : Blood Sample
Shelf life : 24 months
Cell Counter Reagents for Nihon Kohden 5 part Diluent Lyse MEK-7222 CBC Analyzer
Intended Use of Nihon Kohden reagentsTo be used for blood cell counting, sizing, and WBC differentiation, hemoglobin determination on Nihon Kohden MEK-7222 Hematology Analyzers.Specification of Nihon Kohden reagents
| Reagents on Nihon Kohden MEK-8222 MEK-7222 | ||
| Cat. No | Description | Pack Size | 
| DWX-50701 | DILUENT-NK5 | 20L | 
| DWX-50702 | LYSE-NK910 | 500ml×3 | 
| DWX-50703 | LYSE-NK680 | 500ml×3 | 
| DWX-50704 | RINSE520-NK | 5L | 
| DWX-50705 | RINSE620-NK | 5L | 
 
Can send cell counter reagent samples by customer's request?
Of course, our company is preparing some sample for those large consumption currently.
 
Limitations of Detection Method
If the temperature of the reagent is out of the specified range, the specimen's measurement parameters may appear abnormal. If in this condition, please confirm the measurement parameters with the microscopy method. Please refer to the instrument operation manual for details.
Storage
The product should be stored in 2℃-35℃ and the storage period is 2 years. After opening the bottle, it is used in 15℃-30℃, and the validity period is 60 days.
 
Attention
1. This product is an in vitro diagnostic reagent;
2. Pay attention to seal and prevent pollution;
3. Read the instructions carefully before use, and should stop using them when they exceed the period of validity;
4. If the product freezes, it should be completely defrosted at room temperature and used after mixing.
5. Waste liquid, waste, residual products and treatment of contaminated packaging materials, please comply with local regulations;
6. It is strictly forbidden to eat and avoid contact with eyes and skin. Once Contact your eyes and skin,please clean immediately with plenty of water and seek medical advice.
 
Some product questions you may want to ask:
1) What are the reagents of hematology Analyser?
At present, hematology analyzers on the market can be divided into 3 part hematology analyzers and 5 part hematology analyzers. Hematology reagents are also indispensable in the use of hematology analyzer. Hematology reagents include hemolytic agents, diluents, cleaning solutions and concentrated cleaning solutions.
 
2) What is the diluent in the hematology analyzer?
The diluent for the hematology analyzer comprises sodium chloride, sodium sulfate, a phosphate buffer agent, ethylene diamine tetraacetic acid, 1-pyridone-2-sulphur and formaldehyde, and the pH value of the solution is 6.5-7.4, and preferably is 7.2; the content of each component is preferably as follows: 5g/L of ...
 
3) Which diluent is good for RBC and platelet counting?
For this, the blood specimen is diluted (usually in 1:200 ratio) with the help of RBC diluting fluid (commonly the Hayem's Fluid) which preserve and fix the Red blood cells. The Hayem's fluid is isotonic to the Red blood cells and does not cause any damage to it.
 
4) What is the use of Lyse in hematology analyzer?
It is used to lyse (destroy) red blood celis for hemogiobin determinations or aid in the counting of white blood cells. Applicable to the hematology analyzers.
 
5) What is the composition of Lyse for hematology analyzer?
The lytic reagent composition comprises a short chain alkyl oxyethanol selected from the group consisting of 2-methoxyethanol, 2-ethoxyethanol, 2-propoxyethanol, and 2-isopropoxyethanol in a sufficient amount to preserve leukocytes; a non-lysing nonionic surfactant as a debris solublizer; and an inorganic buffer to ...
 
6) Which of the following combination of reagents is used to measure hemoglobin?
This is done by adding both potassium cyanide and ferricyanide whose absorbance is then measured at 540 nm using a photoelectric colorimeter against a standard quality control solution. The Hb concentration is then determined by the result produced by the photoelectric colorimeter.
 
7) What is the principle of 3 part hematology analyzer?
In a 3-part analyzer the cell counting is based on the Coulter Principle. All hematology analyzers utilise Coulter's Principle. 3-part differential cell counter employs Coulter's Principle to determine the size as well as volume of the cells. Coulter's principle is applied employing two electrodes.
 
8) What is a particle cell counterand analyzer reagent?
A variety of reagents that are designed for some cell counters and analyzer that optimize instrument setup, sample preparation and quality control.
|   | 
| Blood Sample Cell Counter Reagents Nihon Kohden 5 Part Diluent Lyse MEK-7222 CBC Analyzer Images | 
 Diluent Lyse Rinse Sysmex Cell Counter Nihon Kohden 3 Part MEK-6400 MEK-6318 ISO
                                                                                        
                                                        
                        
                        
                        
                                                            Diluent Lyse Rinse Sysmex Cell Counter Nihon Kohden 3 Part MEK-6400 MEK-6318 ISO
                                                    
                        
                     Vitro Diagnostic Hematology Beckman Coulter Reagents MAXM Hmx CBC Analyzer With
                                                                                        
                                                        
                        
                        
                        
                                                            Vitro Diagnostic Hematology Beckman Coulter Reagents MAXM Hmx CBC Analyzer With
                                                    
                        
                     LH500 Diluent Lyse Rinse Beckman Coulter Reagents For Hematology Analyzer
                                                                                    
                        
                        
                        
                                                            LH500 Diluent Lyse Rinse Beckman Coulter Reagents For Hematology Analyzer
                                                    
                        
                     Beckman Hematology Reagents Medical Chemistry Analyzer AC.T 5 DIFF Third Party
                                                                                        
                                                        
                        
                        
                        
                                                            Beckman Hematology Reagents Medical Chemistry Analyzer AC.T 5 DIFF Third Party
                                                    
                        
                     High Purity Beckman Coulter Reagents Hematology Analyzer Diagnostic CE CFDA
                                                                                        
                                                        
                        
                        
                        
                                                            High Purity Beckman Coulter Reagents Hematology Analyzer Diagnostic CE CFDA
                                                    
                        
                     CBC Analyzer Cell Counter Reagents Medical Analyser Nihon Kohden Diluent Lyse
                                                                                        
                                                        
                        
                        
                        
                                                            CBC Analyzer Cell Counter Reagents Medical Analyser Nihon Kohden Diluent Lyse
                                                    
                        
                     Diluent Lyse Rinse Cell Counter Nihon Kohden 3 Part MEK-6400 MEK-6318 ISO CE
                                                                                        
                                                        
                        
                        
                        
                                                            Diluent Lyse Rinse Cell Counter Nihon Kohden 3 Part MEK-6400 MEK-6318 ISO CE
                                                    
                        
                     Hematology Analyzer Medical Laboratory Reagents Nihon Kohden Diluent Lyse MEK
                                                                                        
                                                        
                        
                        
                        
                                                            Hematology Analyzer Medical Laboratory Reagents Nihon Kohden Diluent Lyse MEK
                                                    
                        
                     CBC Analyzer Cell Counter Reagents Medical Analyser Nihon Kohden Diluent Lyse
                                                                                        
                                                        
                        
                        
                        
                                                            CBC Analyzer Cell Counter Reagents Medical Analyser Nihon Kohden Diluent Lyse
                                                    
                        
                     Purity CBC Reagent Diluent Lyse Rinse Cell Counter Nihon Kohden 3 Part MEK-6400
                                                                                        
                                                        
                        
                        
                        
                                                            Purity CBC Reagent Diluent Lyse Rinse Cell Counter Nihon Kohden 3 Part MEK-6400